etpengineering@163.com +8613884306400
Summary And Maintenance Of Daily Problems Of Stacked Sludge Dewatering Machine

Summary And Maintenance Of Daily Problems Of Stacked Sludge Dewatering Machine

Aug 13, 2020

When you use the stacked sludge dewatering machine, you will have many daily problems, and the solutions to different situations are different.


1. The sludge dewatering machine does not work. When the snail dehydrator is not working, generally speaking, the electrical wiring should be checked. In the initial operation and debugging, there is no problem with the electrical and wiring. Maybe it is a short circuit or it may be aging. If the route problem is ruled out, we will check whether there is a problem with the reducer. This check is mainly to see whether there is hot or abnormal noise.

 

2. After the switch power supply of the screw stacking machine is started, it can run, but the actual effect of mud output is not good, and the production efficiency is low. Generally speaking, the new screw stacking dehydrator will not have this kind of situation. This kind of situation usually occurs in the machine of four years. In fact, after encountering this kind of situation, you only need to contact the manufacturer of the screw dehydrator and give the spindle bearing of the screw dehydrator to the original screw dehydrator manufacturer for repair. Just run it.

 

3. The machine parts are aging. Find the aging accessories directly and replace them.

 

Solution to abnormal interruption of screw stacker and stop operation


The possible reasons for the interruption of the Stacked sludge dewatering machine are as follows:

 

  1, occlusion occurs

  2, what to do if the voltage is low

  3, accessories are aging

   4. Other reasons: such as manual operation errors or other force majeure factors.

 

In response to the above situation, the solutions are as follows:

 

1. When the screw stacker is blocked (generally speaking, is the screw stacker dehydrator blocked), there is a severe blockage in the pipeline, and the machine may temporarily stop operating. Then the operation requirements must meet the operation details of the screw stacker, which is very suitable for the treatment of fluid mud.


2. What to do if the voltage is low will also affect the abnormal interruption of the snail dehydrator. What to do if the voltage of the snail dewatering machine is low in the operating environment of mines, oil fields, etc., may affect abnormal power failure. Ensure the stability of the power supply voltage and ensure that the power cord meets relevant requirements.


3. The aging of the accessories will also affect the operation of the snail dewatering machine, or even interrupt it abnormally. Such as the aging of the reducer or the dynamic ring has severely exceeded the operating load time.


4. Other man-made operation problems failed to follow the training process, which affected the abnormal interruption of the screw stacker. Need to carry out the operation of the stacking screw dehydrator under guidance.


In any situation, when the screw dehydrator is abnormally interrupted, the switching power supply is generally cut off immediately. The replacement should be replaced, and the maintenance should be performed to ensure that everything is normal before starting operation.

 

Daily maintenance and operation of Stacked sludge dewatering machine


Since its application in the field of sludge dewatering, the stacked screw dewatering machine has gradually replaced the plate frame sludge dewatering machine and belt sludge dewatering machine with its advantages of non-blocking, energy saving, low operating cost, long use time, and simple operation. It is applied in many industries such as municipal sewage treatment plant, printing and dyeing, papermaking, food, breeding, chemical industry, etc.

 

Although the failure rate of the screw dehydrator is low and it can operate smoothly for a long time, the operators should also do the daily inspection and maintenance of the screw dehydrator to increase its service life. Its daily maintenance is mainly to carry out daily inspections and regular inspections of the equipment, and to grasp the condition of the equipment in time.